2012-10-09 - 5173.100 - Spec - SA900 Series Reports #CrystalReportDevelopment
SPECIFICATIONS
5173.100 - SA900 series reports
Requirement Summary
Currently existing SA900 series reports are showing limited data that existed. Need to rebuild SA900 reports to show complete data.
Admin Info
Purpose
|
To show the complete data in SA900 series reports.
|
Requested By
|
Mark Harris
|
Spec Created By
|
Mallareddy D
|
Spec Created Date
|
10/09/2012
|
Spec QA by
|
Uday Kumar P
|
Objects
|
SA900, SA905, SA910, SA915 and SA920 Reports.
|
Document Status
|
Complete
|
References
Prior Tickets
5173.200
Documents
None
Functional Requirement
There are five SA900 series reports as follows:
1. SA900
2. SA905
3. SA910
4. SA915
5. SA920
Above reports are not showing complete information. Need to rebuild above mentioned reports to fetch the complete information and that has to be shown in reports.
Solution Summary
1. Created New BEx queries for the above reports
2. Developed the reports from scratch which is similar to existing reports.
Test Plan
SNo.
|
Test Scenario
|
Expected Results
|
1.
|
Need to test the reports against BEx queries
|
Values should be identical.
|
2.
|
As per NEC Standards
|
Reports should be as per NEC standard checklist.
|
Solution Details
1. Created New BEx queries for the above reports
2. Developed the reports from scratch which is similar to existing reports.
3. Validated the reports before delivering it to NEC.
Issues
Reports were not showing the complete information due to the current version of crystal reports but after upgrading the version to CR 2011 and SP4 the above issues got resolved.